IFM CR0708
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Controllers with high protection requirements |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can CR0708 be shipped?
CR0708 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up CR0708 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for CR0708 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for CR0708, subject to availability and destination.
powerful 32 bit triple core controllers with large application memory With many multifunctional configurable inputs and outputs High-performance CAN and Ethernet interfaces for various communication tasks Freely programmable to IEC 61131-3 with CODESYS 3.5
Specifications
Product characteristics
| Total number of inputs | 20 |
| Total number of outputs | 17 |
| Communication interface | Ethernet; CAN; RS232 |
| Protection | IP 65; IP 67; (for inserted connectors with individually sealed cores and inserted M12 connectors or sealing caps: IP 67) |
Electrical data
| Operating voltage[V] [V] | 8...32 DC; (t < 10 s: 36 V) |
| Nominal voltage DC[V] [V] | 12 / 24 |
| Current consumption[mA] [mA] | < 400 |
| Power consumption[W] [W] | 8; (VBB30) |
| Reverse polarity protection | yes; (in case of supply via the on-board system / battery) |
Inputs / outputs
| Total number of inputs and outputs | 37 |
Inputs
| Total number of inputs | 20 |
| Number of frequency inputs | 8 |
| Number of resistor inputs | 4 |
| Number of digital inputs | 20 |
| Number of analogue inputs | 8 |
| Number | 1 |
| Plug ST A | IN0400...IN0401; IN0900...IN0901 |
| Frequency input | function type; phase; software mode; IN_PHASE_CSO/CSI; frequency [Hz]; 0,0625...5000; switching level high [V]; > 70 % VBB30; switching level low [V]; < 30 % VBB30; input resistance [Ω]; 10000; accuracy; ± 10 µs |
| function type | binary, high side |
| software mode | IN_RESISTOR |
| frequency [Hz] | 0,0625...5000 |
| switching level high [V] | > 70 % VBB30 |
| switching level low [V] | < 30 % VBB30 |
| input resistance [Ω] | 3200 |
| accuracy | 1,6 V |
| Analogue input | function type; Voltage, ratiometric; software mode; IN_VOLTAGE_RATIO; input range [V]; 0...100 % VBB30; input resistance [Ω]; 51000; Resolution; 12 Bit; accuracy; 320 mV; input frequency [Hz]; < 330; diagnostic level low; 0 ‰; (parameterisable); diagnostic level high; 1000 ‰; (parameterisable) |
| input range [V] | 0...100 % VBB30 |
| Resolution | 12 Bit |
| input frequency [Hz] | < 330 |
| diagnostic level low | 0 Ω; (parameterisable) |
| diagnostic level high | 31000 Ω; (parameterisable) |
| Digital input | switching level high [V]; > 70 % VBB30; switching level low [V]; < 30 % VBB30; accuracy; 1,6 V |
| input range [mA] | 0...20 |
| Resistor input | function type; binary, high side; software mode; IN_RESISTOR; input range [Ω]; 16...30000; measuring current [mA]; < 2,0; Resolution; 12 Bit; accuracy; 16...3000 Ω: ± 600 Ω; 3000...15000 Ω: ± 1500 Ω; 15000...30000 Ω: ± 3000 Ω; diagnostic level low; 0 Ω; (parameterisable); diagnostic level high; 31000 Ω; (parameterisable) |
| input range [Ω] | 16...30000 |
| measuring current [mA] | < 2,0 |
Outputs
| Total number of outputs | 17 |
| Number of digital outputs | 16 |
| Number of analogue outputs | 1 |
| Number of PWM outputs | 16 |
| Number of PWM-I outputs | 10 |
| Number of outputs with H-bridge | 4; (2 x 2) |
| Number | 1 |
| Plug ST A | OUT3001 |
| Output group switch | function type; second independent option for safety shut-down of the output group; voltage range [V]; 6...32 DC; voltage measurement [V]; 0...36; accuracy of the voltage measurement [mV]; 360; diagnostic function; current monitoring, voltage monitoring; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 12000; (parameterisable) |
| function type | Voltage |
| voltage range [V] | 0...10 DC |
| voltage measurement [V] | 0...10 |
| accuracy of the voltage measurement [mV] | 500 |
| diagnostic function | wire break; short circuit; current monitoring |
| lower limit of current monitoring [mA] | 0; (parameterisable) |
| upper limit of current monitoring [mA] | 2500; (parameterisable) |
| PWM output | function type; binary, high side; software mode; OUT_PWM_CSO; voltage range [V]; 6...32 DC; switching current [A]; 0,025...2,5; output frequency [Hz]; 20...2000; pulse/pause ratio; 1...1000 ‰; (parameterisable); Resolution; 1 ‰; (20...250 Hz); protective circuitry; inductive load; thermal protection; current measurement [A]; 0...4; accuracy of the current measurement [mA]; 125; diagnostic functions; wire break; short circuit; current monitoring; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 2500; (parameterisable) |
| software mode | OUT_ANALOG_10 |
| switching current [A] | 0,025...2,5 |
| output frequency [Hz] | 20...2000 |
| pulse/pause ratio | 1...1000 ‰; (parameterisable) |
| Resolution | 1 ‰; (20...250 Hz) |
| protective circuitry | inductive load; thermal protection |
| current measurement [A] | 0...2,5 |
| accuracy of the current measurement [A] | 0,04 |
| diagnostic functions | wire break; short circuit; current monitoring |
| PWM-I output | function type; current-controlled; software mode; OUT_CURRENT_CSO; voltage range [V]; 6...32 DC; switching current [A]; 0,025...2,5; output frequency [Hz]; 20...2000; control range [A]; 0,05...2,5; setting resolution [mA]; 1; control resolution [mA]; 2; Min. load resistance [Ω]; 12 V: 3 Ω / 24 V: 6 Ω; protective circuitry; inductive load; thermal protection; current measurement [A]; 0...4; accuracy of the current measurement [mA]; 37,5; diagnostic functions; wire break; short circuit; current monitoring; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 2500; (parameterisable) |
| control range [A] | 0,05...2,5 |
| setting resolution [mA] | 1 |
| control resolution [mA] | 2 |
| Min. load resistance [Ω] | 12 V: 3 Ω / 24 V: 6 Ω |
| Digital output | function type; binary, high side; software mode; OUT_DIGITAL_CSO; voltage range [V]; 6...32 DC; switching current [A]; 0,025...2,5; protective circuitry; inductive load; thermal protection; current measurement [A]; 0...4; accuracy of the current measurement [mA]; 125; switching status monitoring [V]; 2; accuracy of the switching status monitoring [V]; ± 1; diagnostic function; wire break; short circuit; current monitoring; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 2500; (parameterisable) |
| switching status monitoring [V] | 2 |
| accuracy of the switching status monitoring [V] | ± 1 |
| accuracy of the current measurement [mA] | 125 |
| Sensor supply | function type; power supply; software mode; OUT_SENSOR_10; Output voltage [V]; 10; accuracy; 5 %; min. load current [mA]; 10; max. load current [mA]; 200; current measurement A]; 0...2,5; accuracy of the current measurement [mA]; 125; voltage measurement [V]; 0...10; accuracy of the voltage measurement [mV]; 500; diagnostic functions; wire break; short circuit; current monitoring; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 2500; (parameterisable) |
| Output voltage [V] | 10 |
| accuracy | 5 % |
| min. load current [mA] | 10 |
| max. load current [mA] | 5 |
| current measurement A] | 0...2,5 |
| Analogue output | function type; Voltage; software mode; OUT_ANALOG_10; voltage range [V]; 0...10 DC; accuracy; 5 %; max. load current [mA]; 5; step response time [ms]; < 1,8 (10...90 %); voltage measurement [V]; 0...10; accuracy of the voltage measurement [V]; 0,5 V |
| step response time [ms] | < 1,8 (10...90 %) |
| accuracy of the voltage measurement [V] | 0,5 V |
Software / programming
| Parameter setting options | CODESYS 3.5 |
| PLC function to IEC 61131-3 | yes |
| Operating system | Echtzeit-Betriebssystem |
Interfaces
| Communication interface | Ethernet; CAN; RS232 |
| Number of CAN interfaces | 4 |
| Number of Ethernet interfaces | 2 |
| Number of R232 interfaces | 1 |
| Transmission rate | 9,6...115,2 kBit/s |
| Protocol | TCP/IP; UDP/IP; Modbus TCP |
| Profile | CiA DS 301 Version 4.2; CiA DS 401 Version 1.4 |
| Interface | CAN Interface 2.0 A/B ISO 11898 |
| Factory settings | Transmission rate: 115,2 kBit/s |
| Transmission standard | 10Base-T; 100Base-TX |
| Note on interfaces | 2 ports with integrated switch |
Operating conditions
| Housing temperature[°C] [°C] | -40...85 |
| Storage temperature[°C] [°C] | -40...85 |
| Max. relative air humidity[%] [%] | 90; (non condensing) |
| Max. height above sea level[m] [m] | 3000 |
| Protection | IP 65; IP 67; (for inserted connectors with individually sealed cores and inserted M12 connectors or sealing caps: IP 67) |
| Pollution degree | 2 |
| Chemical media | ISO 16750-5; AA, BA, BD, CC, DB, DC, DD |
| ISO 16750-5 | AA, BA, BD, CC, DB, DC, DD |
Tests / approvals
| EMC | DIN EN 61000-6-2 ESD; DIN EN 61000-6-4 Burst; ISO 7637-2 pulse 1; severity level 4 / function state C (24 V); ISO 7637-2 pulse 2a; severity level 4 / function state A (24 V); ISO 7637-2 pulse 2b; severity level 4 / function state C (24 V); ISO 7637-2 pulse 3a; severity level 4 / function state A (24 V); ISO 7637-2 pulse 3b; severity level 4 / function state A (24 V); ISO 7637-2 pulse 4; severity level 4 / function state A (24 V); ISO 7637-2 pulse 5; severity level 3 / function state A (24 V); ISO 7637-2 pulse 4; severity level 4 / function state A (12 V) |
| ISO 7637-2 pulse 1 | severity level 4 / function state C (24 V) |
| ISO 7637-2 pulse 2a | severity level 4 / function state A (24 V) |
| ISO 7637-2 pulse 2b | severity level 4 / function state C (24 V) |
| ISO 7637-2 pulse 3a | severity level 4 / function state A (24 V) |
| ISO 7637-2 pulse 3b | severity level 4 / function state A (24 V) |
| ISO 7637-2 pulse 4 | severity level 4 / function state A (12 V) |
| ISO 7637-2 pulse 5 | severity level 3 / function state A (24 V) |
| Continuous shock resistance | ISO 16750-3; 30 g 6 ms / 24000 shocks |
| ISO 16750-3 | 30 g 6 ms / 24000 shocks |
| Fast temperature change | EN 60068-2-30 damp heat: cyclical; 55 °C upper temperature limit / 6 cycles; EN 60068-2-78 damp heat: constant; 40 °C 93 % rH / test period 21 days |
| EN 60068-2-30 damp heat: cyclical | 55 °C upper temperature limit / 6 cycles |
| EN 60068-2-78 damp heat: constant | 40 °C 93 % rH / test period 21 days |
| Vibration resistance | ISO 16750-3 Test VII; random, mounting place car body; EN 60068-2-6 sine; 10...500 Hz / 10 cycles/axis, sine |
| ISO 16750-3 Test VII | random, mounting place car body |
| EN 60068-2-6 sine | 10...500 Hz / 10 cycles/axis, sine |
| Salt spray test | EN 60068-2-52 Salt spray; severity level 3 / motor vehicle |
| EN 60068-2-52 Salt spray | severity level 3 / motor vehicle |
Mechanical data
| Weight[g] [g] | 1446 |
| Housing | rectangular |
| Type of mounting | screw mounting; (4 x M6) |
| Dimensions[mm] [mm] | 219 x 203 x 47 |
| Materials | housing: diecast aluminium passivated |
Displays / operating elements
| Display | connection; LED, green lights; data transmission; LED, green flashing |
| status (SYS0) | 1 LED, multi-colour |
| status (SYS1) | 1 LED, multi-colour |
| Ethernet (ETH0) | 1 LED, green |
| Ethernet (ETH1) | 1 LED, green |
| status (APP0) | 1 LED, multi-colour programmable |
| status (APP1) | 1 LED, multi-colour programmable |
| status (APP2) | 1 LED, multi-colour programmable |
| status (APP3) | 1 LED, multi-colour programmable |
| kein Betriebssystem geladen | LED (SYS0), green flashing 5 Hz |
| Hardware-Fehler (Fatal Error+) | LED (SYS0), red lights |
| System-Fehler (Fatal Error) | LED (SYS0), red lights |
| Update | LED (SYS0), yellow/green flashing 2 Hz |
| Sleep Mode | LED (SYS0), blue lights |
| keine Applikation | LED, green lights |
| Run | LED, green flashing 2 Hz |
| fault | LED, red flashing 10 Hz |
| Debug Run | LED, yellow flashing 2 Hz |
| Debug Stop | LED, yellow lights |
| connection | LED, green lights |
| data transmission | LED, green flashing |
Hardware
| Processor | 32-Bit Triple-Core |
| RAM | 2,7 MByte RAM |
| Mass storage | 9 MByte Flash |
| Non-volatile memory | 10 kByte |
Accessories
| Items supplied | Protective cap: M12; self-tapping screw: 1 x M4, for shield connection |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - CAN0
| Connector | 1 x M12; coding: A |
Electrical connection - CAN1 / RS232
| Connector | 1 x M12; coding: A |
Electrical connection - Ethernet
| Connector | 2 x M12; coding: D |
Electrical connection - ST A
| Connector | 1 x AMP; coding: A |